Fuel Pump: Service Precautions
WARNING: Adhere to the following procedures any time the fuel system is being worked on in order to reduce the risk of fire and personal injury:* Keep a dry chemical (Class B) fire extinguisher near the work area.
* Place a "CAUTION FLAMMABLE" sign in the work area.
* Work in a well-ventilated area. Do not smoke, and keep sparks and open flames away.
* Wear eye protection.
* Use caution when working near the catalytic converter to prevent the possibility of burns or fire. (The temperatures within the converter can exceed 537 degrees C (1000 degrees F)).
* Relieve the fuel system pressure prior to disconnecting fuel system components.
* Disconnect the negative battery cable except for tests where battery voltage is required.
* Use a suitable container to store or catch fuel.
* Do not replace fuel pipe with fuel hose.
* Plug all disconnected fuel line fittings and hoses.
* After making any fuel system repairs ALWAYS inspect for fuel leaks.