Starting System - Vehicle Start After Battery Depletion
ELECTRICALEL017-06
Title:
VEHICLE START AFTER
BATTERY DEPLETION
Models:
'05 - '07 Avalon & '07 Camry
December 22, 2006
Introduction
In vehicles equipped with the Smart Key system, the starting function may not be operational after recharging a discharged battery or jump starting the vehicle. If battery voltage drops below 9V, the Steering Lock ECU may need to be re-initialized. Follow the initialization procedure below to re-initialize the Steering Lock ECU.
Applicable Vehicles
^ 2005 - 2007 model year Avalon vehicles.
^ 2007 model year Camry vehicles.
Initialization
Procedure
1. Confirm that the DCC fuse is installed.
NOTE:
If DCC fuse is NOT installed, install at this time.
2. Place the shift lever in the "P" position.
3. Open and close the driver's side door.
NOTE:
This will start an initialization process between the Steering Lock ECU and the Junction Block ECU.
4. Depress the brake pedal.
5. Press the engine "START STOP" switch.
6. Re-initialize any affected power systems.
2005 model year Avalon:
^ Refer to TSB No. PD008-05, "Power System Initialization During PDS".
2006 model year Avalon:
^ Refer to TSB No. PD014-06, "Power System Initialization During PDS".
2007 model year Avalon:
^ Refer to TSB No. PD055-06, "Initialization of Sliding Roof During PDS".
^ Refer to TSB No. PD057-06, "Initialization of Power Window During PDS".
Warranty Information