Initialization
INITIALIZATION1. STEP MOTORS INITIALIZING FUNCTION
Step motor initializing procedure (Automatic initializing)
1. When the battery is reconnected and the ignition switch is turned to the on (IG) for the first time, the initializing function of the step motors is activated.
In this case, the "FRONT DEF" indicator blinks.
HINT: Initialization will be automatically completed after several seconds.
2. If mode indication is different from the actual air outlet in actuator check, turn the ignition switch on (IG) while pressing the "Rr. DEF" and "OFF" switches simultaneously. Step motor initialization occurs and the "FRONT DEF" indicator blinks.