Operation CHARM: Car repair manuals for everyone.

Heated Oxygen Sensor

OXYGEN SENSOR

REPLACEMENT




1. REMOVE OXYGEN SENSOR
a. Disconnect the 2 oxygen sensor connectors.
b. Remove the 2 oxygen sensors from the front pipe assembly.

SST 09224-00010




2. INSTALL OXYGEN SENSOR
a. Install the 2 oxygen sensors to the front pipe assembly.

SST 09224-00010

Torque:
44 N.m (449 kgf.cm, 32 ft.lbf)
40 N.m (408 kgf.cm, 30 ft.lbf) (with SST)

NOTE: Use a torque wrench with a fulcrum length of 300 mm (11.81 in.).

b. Connect the 2 oxygen sensor connectors.