Blower Motor: Testing and Inspection
HEATING / AIR CONDITIONING: FRONT BLOWER MOTOR: INSPECTION
1. INSPECT BLOWER MOTOR
(a) Disconnect the connector from the blower motor.
(b) Connect a positive (+) lead from the battery to terminal 2 and a negative (-) lead from the battery to terminal 1, and check that the motor operates.
OK:
The blower motor operates smoothly.
If the result is not as specified, replace the blower motor.