System Description
WIPER / WASHER: WIPER AND WASHER SYSTEM: SYSTEM DESCRIPTION
1. WASHER LINKED OPERATION
(a) for front:
(1) This system operates the front wipers at low speed immediately after a jet of washer fluid when the front washer switch is turned on for 0.3 seconds or more. The system operates the front wipers at low speed for approximately 2.2 seconds and then stops operation when the washer switch is turned on for 1.5 seconds or more.
(b) for rear:
(1) This system operates the rear wiper when the rear washer switch is turned to ON+WASHER. The time from turning the washer switch to the ON+WASHER position to activating the rear wiper motor is approximately 0.5 seconds.
2. INTERMITTENT OPERATION
(a) The system operates the front wipers once approximately every 1.6 to 10.7 seconds when the front wiper switch is turned to the INT position. The intermittent time can be adjusted from 1.6 to 10.7 seconds by using the intermittent time adjustment dial.
(b) If the wiper control switch is turned to the INT position, current flows from the already charged capacitor C1 through terminals INT1 and INT2 of the wiper control switch to Tr1 (transistor). When Tr1 turns on, current flows from terminal +S of the wiper control switch to terminal +1 of the wiper control switch, to terminal +1 of the wiper motor, to the wiper motor and finally to ground, causing the wiper motor to operate. At the same time, current flows from capacitor C1 to terminal INT1 of the wiper control switch and then INT2. When the current flow from capacitor C1 ends, Tr1 turns off to stop the relay contact point and halt the wiper motor.
When the relay contact point turns off, capacitor C1 begins to charge again and Tr1 remains off until charging has been completed. This period corresponds to the intermittent time. When capacitor C1 is fully charged, Tr1 turns on and then the relay contact point turns on, causing the motor to operate again. This cycle is the intermittent operation.
The intermittent time can be adjusted by using the intermittent time adjustment dial (variable resistor) to change the charge time of capacitor C1.