Operation CHARM: Car repair manuals for everyone.

Odometer: Service and Repair




Adaptation (function 10)

Use this function to initiate and store the following changes:
- Adaptation of odometer reading when replacing/exchanging instrument cluster.
- Adaptation of fuel gauge reading.
- Adaptation of Multi-function Indicator (MFA) fuel consumption indicator (where applicable).

Individual functions are called up using the appropriate channel number from adaptation table.

Adaptation table:







Odometer, Adaptation


NOTE:
- Market and equipment appropriate coding of instrument cluster must be performed before adaptation of odometer reading.
- The total distance travelled by the vehicle can be read from the malfunctioning instrument cluster or determined by the vehicle service history.
- The total distance travelled display of new instrument cluster must not be more than 100 km (62 mi) before adaptation.
- The total distance travelled to be transferred to the new instrument cluster must exceed 100 km (62 mi).
- Adapting the total distance travelled is only possible once and only in a positive (upwards) direction.
- Adaptation can be interrupted with the "C" button of the VAG 1551.
- Correcting a false entry which has been confirmed is not possible. The instrument cluster must be exchanged for a new one.
- Adaptation value must be entered in kilometers. For US models, adaptation value must be converted from miles to kilometers first (miles x 1.609 = kilometers).


Adaptation, example
The malfunctioning instrument cluster has an odometer reading of 89627 km. This reading is transferred to the new instrument cluster as follows:
- Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press -> button until "Select function"is displayed..


NOTE: Login procedure is only needed for VDO instrument clusters. On Motometer instrument clusters, adaptation functions can be selected immediately.


Indicated on display:


Rapid data transfer HELP
Select function XX



- Press button -1- twice to select "Login" function 11.
- Press -Q- button to confirm input.

Indicated on display:


Rapid data transfer Q
11 - Login procedure



- Press -Q- button to confirm input.

Indicated on display:


Login procedure Q
Enter code number XXXXX



- Enter code number 13861.

Indicated on display:


Login procedure Q
Enter code number 13861



"FAIL" appears in odometer if a false code or secret number is entered 3 times.

In this case terminal 30 (battery) must be disconnected and reconnected again and the Login procedure repeated using the correct code number.

- Press -Q- button to confirm input.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display:


Rapid data transfer Q
10 - Adaptation



- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Enter channel number XX



- Press buttons -0- and -9- to select adaptation "channel 09".
- Press -Q- button to confirm input.

- Indicated on display:


Channel 9 Adaptation 0 ->
<-1 3->



- Press -> button to advance program sequence.

Indicated on display:


Channel 9 Adaptation 0
Enter adaptation value XXXXX



- Enter adaptation value using VAG 1551 button pad.

The last position of the kilometer reading must be rounded off to the nearest 10 kms. Therefore, a kilometer reading of 89627 produces an adaptation value of:

0 8 9 6 3







- After entering adaptation value using VAG 1551 button pad.

Indicated on display (example only):


Channel 9 Adaptation 0 Q
Enter adaptation value 08963



- Press -Q- button to confirm input.

Indicated on display:


Channel 9 Adaptation 8963 Q
<-1 3->



The kilometer reading entered now appears in the display of the instrument cluster. If the displayed kilometer reading is not OK, e.g. false entry:
- Press -C- button and enter correct adaptation value again.

If the displayed kilometer reading in instrument cluster is OK:
- Press -Q- button to confirm input.

Indicated on display:


Channel 9 Adaptation 8963 Q
Store changed value?



- Press -Q- button to confirm input.

Indicated on display:


Channel 9 Adaptation 8963 ->
Changed value is stored



- End odometer adaptation by pressing -> button.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -6- to select "End Output" function 06.

Indicated on display:


Rapid data transfer Q
06 End Output



- Press -Q- button to confirm input.

Indicated on display:


Rapid data transfer Help
Enter address word XX



The tester is now in basic function again.

Distance impulse number (K number), reading/confirming

Distance impulse number can only be read/confirmed on VDO instrument clusters.


NOTE:
- The distance impulse number is a constant used to calculate the speed indication and distance travelled.
- The distance impulse number (K number) cannot be changed using the "Adaptation" function. To change the distance impulse number, a code that corresponds to the vehicle engine/gearbox combination must be entered using "Code Control Module" function 07.
- For instrument clusters with mile indicators, the distance impulse number is shown in kilometers. The trip impulse number for mile values can be calculated as follows: Trip impulse number for kilometer values x 1.609 = trip impulse number for mile values.
- Press the -C- button on the VAG 1551 to abort the "Read distance impulse number" function.


- Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press -> button until "Select function" appears in display.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display:


Rapid data transfer Q
10 - Adaptation



- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Enter channel number XX



- Press buttons -1- and -6- to select adaptation "channel 16".
- Press -Q- button to confirm input.

Indicated on display (example only):


Channel 16 Adaptation 3538 ->
<-1 3->



- Read/confirm distance impulse number in accordance with production date and/or vehicle engine/gearbox combinations.

- Interrupt "Reading distance impulse number" with "C" button.

Indicated on display:


Adaptation
Enter channel number XX



- Press "C" button.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -6- to select "End Output" function 06.

Indicated on display:


Rapid data transfer Q
06 - End Output



- Press -Q- button to confirm input.

Indicated on display:


Rapid data transfer Help
Enter address word XX



The tester is now in basic function again.