Instrument Cluster From 10.00, Coding (Function 07)
Instrument cluster, coding (function 07)
Use this function to code the control module with indicator unit in instrument cluster -J285- with the following information:
- Available equipment
- Market version
- Code number for service intervals
- Code number for distance impulse number ("K" number)
Coding
- Connect VAG 1551 scan tool (ST), select operating mode 1 "Rapid data transfer", switch on ignition and input address word 17 "Instrument cluster".
After control module identification and immobilizer identification number are displayed:
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -7- to select function 07 "Code control module".
Indicated on display:
Rapid data transfer Q
07- Code control module
- Press -Q- button to confirm input.
Indicated on display:
Code Control Module
Enter code number XXXXX (0 - 32000)
- Confirm applicable available equipment, model and service interval particulars, determine and enter code number from code table. Instrument Cluster
Coding example:
03 Code number for vehicle options
2 Code number for country version
3 Code number for service intervals
2 Code number for distance impulse number (K-number)
Code table:
1) If more than one type of available equipment is to be entered, then the code numbers must be added together.
Example:
Brake pad wear indicator & seat belt warning: 01 + 02 = 03
NOTE:
- The distance impulse number is a constant used to calculate speed and distance travelled.
- The distance impulse number (K number) can be read using function 10 "Adaptation".
Indicated on display:
Code Control Module Q
Enter code number 03202 (0 - 32000)
- Press -Q- button to confirm input.
Indicated on display (example only):
1C0920901C A4 COMBI INSTR VDO V04 ->
Coding 03202 WSC 00000
- Press -> button.
Indicated on display:
IMMO-IDENT No.: VWZ7Z0V0066808 ->
- Press -> button.
Indicated on display (select function)
Rapid data transfer HELP
Select function XX
Ending function:
- Press buttons -0- and -6- to select function 06 "End output".
Indicated on display:
Rapid�data transfer Q
06 - End output
- Press -Q- button to confirm input.