Mass Air Flow (MAF) Sensor, Checking
Mass Air Flow (MAF) Sensor, Checking
NOTE: Use only gold-plated terminals when servicing terminals in the harness connector.
Recommended special tools and equipment
- V.A.G1526 multimeter or V.A.G1715 multimeter
- V.A.G1594 connector test kit
- Wiring diagram
Test requirements
- Corresponding fuses on fuse holder in instrument panel, left side, for Mass Air Flow (MAF) Sensor -G70- must be OK.
NOTE: Fuses on this fuse holder are labelled "SC" in the wiring diagram.
- Battery voltage must be at least 11.5 Volts.
- All electrical consumers such as, lights and rear window defroster must be switched off.
- Ground (GND) connections between engine and chassis must be OK.
- For vehicles with automatic transmission, selector lever must be in -P-.
- Coolant temperature must be at least 80 degrees C; PID 5 ($5), Coolant temperature.
- Air filter not blocked or soiled.
- Intake system properly sealed.
- Ignition switched off.
Function test
Observe safety precautions.
Observe rules for cleanliness.
- Connect diagnostic tester.
- Start engine and let run at idle.
- Under address word 33, select "Diagnostic mode 1: Checking measured values."
- Select measuring value "PID 16 ($10): Air flow quantity at Mass Air Flow (MAF) sensor":
- Check specified value of air flow quantity at Mass Air Flow (MAF) Sensor at idle:
- End diagnosis and switch ignition off.
If specified value is obtained, but DTC memory has a DTC concerning Mass Air Flow (MAF) sensor:
- Check voltage supply.
- Erase DTC memory of Engine Control Module (ECM). Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. Monitors, Trips, Drive Cycles and Readiness Codes
If specified value is not obtained:
- Check wires to Engine Control Module (ECM) according to wiring diagram.
Checking voltage supply
- Disconnect 5-pin connector -1- from Mass Air Flow (MAF) Sensor -G70-.
- Connect multimeter using adapter cables to terminal 3 of connector and engine Ground (GND) for voltage measurement.
- Start engine, and let run at idle.
Specified value: at least 11.0 V
- Switch ignition off.
If there is a malfunction in voltage supply:
- Check wire between 5-pin connector terminal 3 and fuse holder for open circuit according to wiring diagram.
Wire resistance: max. 3.0 Ohms
If there is no malfunction in voltage supply:
- Connect multimeter using adapter cables to terminal 1 of connector and engine Ground (GND) for voltage measurement.
- Switch ignition on.
Specified value: at least 4.5 V
- Switch ignition off.
If there is a malfunction in voltage supply:
- Check wires to Engine Control Module (ECM) according to wiring diagram.
Checking wires to Engine Control Module (ECM)
- Disconnect 5-pin connector -1- from Mass Air Flow (MAF) Sensor -G70-.
- Connect test box to 94-pin connector of wiring harness. Test Box, Connecting For Wiring Test
Engine Control Module (ECM) is not connected.
- Check wires between test box and 5-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Terminal 1 + socket 22
Terminal 2 + socket 1
Wire resistance: max. 3.0 Ohms
- Check wires for short circuit to each other.
Specified value: Infinity Ohms
- Erase DTC memory of Engine Control Module (ECM). Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. If no DTCs are found in wires:
- Replace Mass Air Flow (MAF) Sensor -G70-, item 1
- Erase DTC memory of Engine Control Module (ECM). Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. Monitors, Trips, Drive Cycles and Readiness Codes