Operation CHARM: Car repair manuals for everyone.

Checking Ground Lead Resistance [EB4]



Checking Ground Lead Resistance





- Ignition off.
- Disconnect pedal sensor.
- Disconnect control module.

Connect an ohmmeter between pedal sensor connector terminal 2 and #41 on test box.

Ohmmeter should read approx. 0 Ohms.

If reading is OK:
- Check signal lead for short to ground lead EB5. Check If Signal Lead Shorted to Ground Lead [EB5]

If reading is incorrect:





- Check lead between pedal sensor connector terminal 2 and control module #41 for open circuit as per HA2. Open Circuit [HA2]