Check Signal Lead [EH5]
Check Signal Lead
- Ignition off.
- Disconnect connector C/ED.
Connect an ohmmeter between hydraulic unit connector C/ED terminal 13 (towards control module) and #13 on test box.
Ohmmeter should read approx. 0 Ohms.
If reading is OK:
- Check lead between hydraulic unit connector C/ED terminal 14 and control module #26 for open circuit as per HA2. Open Circuit [HA2]
If reading is incorrect:
- Check lead between hydraulic unit connector C/ED terminal 13 and control module #13 for open circuit as per HA2. Open Circuit [HA2]