Intermittent Fault [EH11]
Intermittent Fault Check Leads And Terminals.
- Check hydraulic unit connector C/ED and control module connector for loose contact as per HA5 and contact resistance and oxidation as per HA6. Checking Leads and Connections [HA]
- Check leads between hydraulic unit and control module #13 and #26 for intermittent open circuit as per HA2, intermittent short-circuit to ground as per HA3 and intermittent short-circuit to supply as per HA4. Checking Leads and Connections [HA]