Intermittent Fault
Intermittent fault
Identification of control module version
Different fault-tracing should be carried out depending on the control module version Note the identification code in the lower left corner of the control module product plate
Does the identification code begin with "S1." ?
Yes - Check leads and connections
No - Erasing DTCs
-------------------------------------------------
Check leads and connections
Check the cable between the battery plus terminal and control unit #9 for intermittent breaks Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Select Continue when the fault has been repaired
Continue - Erasing DTCs
-------------------------------------------------
Erasing DTCs
- Ignition on
- Erase the DTC
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Check leads and connections
-------------------------------------------------