Signal Too Low
Signal too low
Status check
- Start engine.
- Go into rolling values.
- Read off status of generator (GEN) charge voltage.
Is the status high?
Yes - Faulty signal. Intermittent fault
No - Checking the charging system
-------------------------------------------------
Checking the charging system
Check charging system for low charge voltage.
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair check that the fault has been remedied.
- Ignition off.
- Reinstall connectors, components etc.
- Start engine.
- Go into rolling values.
Read off status of generator (GEN) charge voltage.
Is the status high?
Yes - FAULT FOUND
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Status check
-------------------------------------------------
Faulty signal. Intermittent fault
Faulty signal. Intermittent fault
Checking cables and terminals
Check charging system for intermittent low charge voltage fault causes.
Continue - Fault-tracing information
DONE
------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
-------------------------------------------------
Attempt New Test - Status check
-------------------------------------------------