Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
EFI-212 Front heated oxygen sensor (HO2S), signal
Checking cables
- Check cable between front heated oxygen sensor (HO2S) terminal 4 and engine control module (ECM) #A32 for an intermittent short-circuit to the cable between front heated oxygen sensor (HO2S) terminal 3 and engine control module (ECM) #A33.
Continue - Fault-tracing information
Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking cables
-------------------------------------------------