Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
EFI-314 Camshaft position (CMP) sensor, signal
Checking cables and terminals
- Check camshaft position (CMP) sensor and engine control module (ECM) connectors for loose connections according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults and contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
- Check cable between camshaft position (CMP) sensor terminal 1 and engine control module (ECM) #A18 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
- Check cable between the camshaft position (CMP) sensor terminal 2 and engine control module (ECM) #A21 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults , an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults , and an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
- Check cable between camshaft position (CMP) sensor terminal 3 and engine control module (ECM) #A36 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Select "Continue" when the fault has been repaired.
Continue - Fault-tracing information
Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking cables and terminals
-------------------------------------------------