Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
EFI-445 Pulsed secondary air injection system (PAIR) pump, signal.
Checking cables and terminals
- Check cable between pulsed secondary air injection system (PAIR) pump relay terminal B1 and engine control module (ECM) #B38 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Continue - Fault-tracing information
Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking cables and terminals
-------------------------------------------------