Signal Missing. Intermittent Fault
Signal missing. Intermittent fault
EFI-616 EVAP canister shut-off valve, signal
Identification
First read Identifying cars constructed according to ORVR Application and ID.
Is the car constructed according to ORVR?
Yes - Safety
No - Signal missing. Intermittent fault
-------------------------------------------------
Signal missing. Intermittent fault
EFI-616 EVAP canister shut-off valve, signal
Checking cables and terminals
- Check EVAP canister shut-off valve and/or engine control module (ECM) connectors for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults and loose connections according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
- Check cable between EVAP canister shut-off valve terminal 1 and main relay (2/32) terminal 3 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
- Check cable between EVAP canister shut-off valve terminal 2 and engine control module (ECM) #B19 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Continue -
------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test -
-------------------------------------------------
-------------------------------------------------
Safety
First read Safety regulations for handling fuel Safety Regulations For Handling Fuel.
Continue - Checking cables and terminals
-------------------------------------------------
Checking cables and terminals
Check EVAP canister shut-off valve and/or control module connector for contact resistance and oxidation. Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults , and loose connections. Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check cable between EVAP canister shut-off valve terminal 1 and main relay (2/32) terminal 3 for an intermittent open-circuit. Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check cable between EVAP canister shut-off valve terminal 2 and engine control module (ECM) #B19 for an intermittent open-circuit. Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Attempt New Test - Checking cables and terminals
-------------------------------------------------