Operation CHARM: Car repair manuals for everyone.

Signal Too Low. Permanent Fault






Signal too low. Permanent fault

EFI-616 EVAP canister shut-off valve, signal

Identification
First read Identifying cars constructed according to ORVR Application and ID.

Is the car constructed according to ORVR?

Yes - Safety

No - Signal too low. Permanent fault

-------------------------------------------------






Signal too low. Permanent fault

EFI-616 EVAP canister shut-off valve, signal

Checking for a short-circuit
Check cable between solenoid valve terminal 2 and engine control module (ECM) #A37 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.





Continue -

------------------------

Verification




Verification

Hint: After carrying out the repair, check that the fault has been remedied as follows:












- Ignition off.
- EVAP canister shut-off valve and engine control module (ECM) connected.
- Ignition on.




- Select Volvo Scan Tool (ST) to activate EVAP canister shut-off valve.
- The EVAP canister shut-off valve clicks when it is activated.

Is the EVAP canister shut-off valve working?

OK - VERIFIED

Not OK - VERIFICATION FAILED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED -

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit fault-tracing

No - Attempt New Test

------------------------

Attempt New Test -

-------------------------------------------------


-------------------------------------------------

Safety
First read Safety regulations for handling fuel Safety Regulations For Handling Fuel.

Continue - Checking for a short-circuit

-------------------------------------------------

Checking for a short-circuit
Check cable between EVAP canister shut-off valve terminal 2 and engine control module (ECM) #B19 for a short-circuit to ground. Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.













Continue - Verification
Signal missing. Permanent fault Signal Missing. Permanent Fault

-------------------------------------------------

Verification




Verification

Hint: After carrying out the repair, check that the fault has been remedied as follows:












- Ignition off.
- EVAP canister shut-off valve and engine control module (ECM) connected.
- Ignition on.
Activate EVAP canister shut-off valve.
The EVAP canister shut-off valve clicks when it is activated.





Is the EVAP canister shut-off valve working?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information
Information
Attempt New Test - Checking for a short-circuit

-------------------------------------------------