Signal Too High
Signal too high
Checking signal from airing module
- Ignition on.
- Go into rolling values.
- Read off airing module status.
The value should be OFF.
Is the value OFF?
Yes - Intermittent
No - Checking cables
-------------------------------------------------
Checking cables
Check the cable between the control module #A21 and the airing module terminal 5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Select "Continue" when the fault has been repaired.
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows:
- Ignition on.
- Reinstall connectors, components etc.
- Go into rolling values.
- Read off airing module status.
The value should be OFF.
Is the value OFF?
Yes - FAULT FOUND
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Verification indicates that the fault persists.
Do you want to repeat fault-tracing?
Yes - Checking signal from airing module
No - No Fault Found
-------------------------------------------------
Intermittent
Check the cable between control module #A21 and airing module terminal 5 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
Do you want to repeat fault-tracing?
Yes - Checking signal from airing module
No - No Fault Found
-------------------------------------------------