Operation CHARM: Car repair manuals for everyone.

Internal Fault






Internal fault

Checking the control module




- Ignition on.
- Disconnect the Volvo Scan Tool (ST) from the VIDA station. Use it in stand alone mode and connect it to the data link connector (DLC) in the car.
- Use the System test function to test the control module internal circuits (GPS). For more information about the System test, see System Test System Test. The test can take up to approximately 40 seconds.
Check if the control module is OK or not.
If control module works OK is displayed.





Is the control module OK?

Yes - Intermittent fault

No - Replacing component

-------------------------------------------------

Replacing component

Hint: The control module contains a number of settings that the users can program in themselves. If possible these settings should be read off and noted down before the control module is replaced. So that the new control module can be programmed in the same way.

Other information:
Try a new control module according to Replacing the control module, old system Replacing the Control Module, Old System.

Continue - Verification

-------------------------------------------------

Verification

Hint: After carrying out the repair, check that the fault has been remedied.












- Ignition off.
- Reconnect connectors, reinstall components.
- Disconnect the Volvo Scan Tool (ST) from the VIDA station. Use it in stand alone mode and connect it to the data link connector (DLC) in the car.
- Ignition on.
- Use System test function to test the control module circuits (GPS). For more information about the System test, see System Test System Test. The test can take up to approximately 40 seconds.
Check if the control module is OK or not.
If control module works OK is displayed.





Is the control module OK?

Yes - FAULT FOUND

No - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit fault-tracing

No - Attempt New Test


-------------------------------------------------

Intermittent fault
The fault tracer indicates that the control module had previously identified an internal fault but that the fault is no longer apparent.






Continue - Fault-tracing information
FAULT FOUND

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND


-------------------------------------------------