Signal Too Low. Intermittent Fault






Signal too low. Intermittent fault

Intermittent fault








- Ignition off.
- Disconnect the connector from the seat belt tensioner.
- Ignition on.
Connect an oscilloscope between seat belt tensioner 1 and ground. Take a reading for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults. The oscilloscope should indicate a spiked pulse with an interval of approximately 500 ms and an offset off approximately 2 V.
If the value deviates there is a short-circuit in the cable. Replace the cable harness.
Also take readings between seat belt tensioner 2 and ground.
The oscilloscope should read approximately 2 V.
Remedy as necessary.









Select Continue when the fault has been remedied.

Continue - Fault-tracing information
DONE

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

FAULT-TRACING FAILED - DONE

Attempt New Test - Intermittent fault

-------------------------------------------------