Checking Special Tool 861 8437
Calibration
861 8437 SRS adapter C70 ,S70,V70 861 8437 SRS Adapter
General
It is important that the special tool is operating correctly when fault-tracing and inspecting the SRS system. A defective special tool will cause the on-board diagnostic (OBD) system to give false readings and will make fault-tracing and checking more difficult.
The special tool must be calibrated using an ohmmeter before it is used to ensure that is fault free it.
Continue - Removing resistance
-------------------------------------------------
Removing resistance
- Remove the resistance by removing the section illustrated.
Check for any damage to the connector and wiring.
Continue - Diagnostic testing of the resistance
-------------------------------------------------
Diagnostic testing of the resistance
Use an ohmmeter to read off the resistance in the special tool.
- Connect the ohmmeter test probes to the special tool terminals as illustrated.
The ohmmeter should read between 1.65 and 2.35 ohms
OK - Fault-tracing information 1
Not OK - Fault-tracing information 2
-------------------------------------------------
Fault-tracing information 1
The special tool is OK.
- Remove the piece of hose from the pins.
DONE
-------------------------------------------------
Fault-tracing information 2
The special tool is defective.
- Scrap the tool and replace it with a new one
FAULT FOUND
-------------------------------------------------