Checking Signal From Hood Switch
Checking signal from hood switch
- Ignition on.
- Hood open.
- Go into rolling values.
- Read off the hood switch status.
The value should be HIGH when the hood is open.
Is the value HIGH?
Yes - No Fault Found
No - Checking for a short-circuit to ground
-------------------------------------------------
Checking for a short-circuit to ground
Check cable between VGLA control module #A3 and hood switch terminal 1 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Were any faults found in the cable?
Yes - Verification
No - Replacing component
-------------------------------------------------
Replacing component
Replace hood switch according to Replacing the hood catch and the micro-switch Service and Repair.
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair check that the fault has been remedied.
- Ignition off.
- Reconnect connectors, reinstall components.
- Ignition on.
- Hood open.
- Go into rolling values.
- Read off the hood switch status.
The value should be HIGH when the hood is open.
Is the value HIGH?
Yes - Fault has been remedied
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
-------------------------------------------------