Trouble Code Conditions
Checking Wiring And Connections
- Check that the fresh air intake is intact and properly connected.
- Check cable between main relay (2/32) terminal 3 and mass air flow (MAF) sensor terminal 3 for an intermittent open-circuit.
- Check cable between mass air flow sensor terminal 4 and engine control module (ECM) # A4 for an intermittent open-circuit and intermittent short-circuit to ground.
Fault-tracing Information
For intermittent faults fault-tracing is not followed by a verification because the fault is not present at this moment.
- Do you want to repeat fault-tracing?
Yes:
^ Return to Checking Wiring And Connections section above.
No:
^ Operation done.