Operation CHARM: Car repair manuals for everyone.

Signal Missing. Intermittent Fault





Checking Wiring And Connections

CAUTION: Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.

- Check cable between front heated oxygen sensor terminal 4 and engine control module (ECM) # A32 for an intermittent open-circuit.
- Check cable between front heated oxygen sensor terminal 3 and engine control module # A33 for an intermittent open-circuit.
- Check engine control module and front heated oxygen sensor connectors for loose connections.

Then continue with:
^ Proceed to test step below.

Fault-tracing Information
For intermittent faults fault-tracing is not followed by a verification because the fault is not present at this moment.