Operation CHARM: Car repair manuals for everyone.

Signal Too High. Intermittent Fault












Checking cables and terminals
Check cable between EVAP canister shut-off valve terminal 2 and engine control module (ECM) #B19 for an intermittent short-circuit to supply voltage.

Then continue with:
^ Operation done