Signal Too Low. Permanent Fault
Checking for a short-circuit
Check cable between EVAP canister shut-off valve terminal 2 and engine control module (ECM) #B19 for a short-circuit to ground.
Then continue with:
^ Proceed to next step below.
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows:
- Ignition off.
- EVAP canister shut-off valve and engine control module (ECM) connected.
- Ignition on.
Activate EVAP canister shut-off valve. See: Activating Components / Functions section.
The EVAP canister shut-off valve clicks when it is activated.
Is the EVAP canister shut-off valve working?
Yes:
^ Fault corrected
No:
^ Fault not found