Operation CHARM: Car repair manuals for everyone.

Checking the Compressor and the Condenser Fan






Checking the compressor and the condenser

Connecting the breakout box





Connecting the breakout box
981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 981 3194 Replaced by 9511495 981 3194 Replaced by 951 1495
Breakout box and checking ground terminals

Is the breakout box connected? Have the ground terminals been checked?

Yes - DONE

No - Areas of use for the breakout box

------------------------

Areas of use for the breakout box
Breakout box 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 is designed to facilitate reading off:
- the control module input and output signals when the control module is connected
- the resistance of cables and components when the control module is disconnected
The breakout box makes it safer to take readings because it is easier to see and access measurement points. The risk of accidental short-circuits and damaged connector pins is also reduced.
Switch off the power to the ECC control module when connecting the breakout box otherwise the control module may be damaged and incorrect diagnostic trouble codes (DTCs) stored.





Select Continue.

Continue - Connecting the breakout box

------------------------

Connecting the breakout box






Select one of the above options to continue.

1 - Connecting the breakout box between the control module and the wiring

2 - Connecting the breakout box to the wiring only

------------------------

Connecting the breakout box between the control module and the wiring








- Ignition off.
- ECC control module connected.
Check the control module and the control module connector visually according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault
Connect adapter 981 3194 Replaced by 9511495 981 3194 Replaced by 951 1495 (only the 30-pin connector) between the ECC control module and the climate control connector. Then connect breakout box 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 to the adapter. This is connection is carried out when taking readings with the control module connected.
Control module connector terminals #1- #30 correspond to terminals #1-#30 on the breakout box.





Select Continue.

Continue - Checking ground terminals

------------------------

Connecting the breakout box to the wiring only








- Ignition off.
- Disconnect the ECC control module.
Check the control module and the control module connector visually according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault
Connect adapter 981 3194 Replaced by 9511495 981 3194 Replaced by 951 1495 (only the 30-pin connector) to the climate control system connector. Then connect breakout box 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 to the adapter. The breakout box is now only connected to the climate control connector. This connection is used to measure resistance in the ECC system cables and components with the ECC control module disconnected.
Control module connector terminals #1- #30 correspond to terminals #1-#30 on the breakout box.





Select Continue.

Continue - Checking ground terminals

------------------------

Checking ground terminals




- Ignition off.
Connect an ohmmeter between the chassis and terminal #3 to check the power ground.









The ohmmeter should read 0ohms.

OK - Checking ground terminals

Not OK - Checking for an open-circuit

------------------------

Checking ground terminals
Connect an ohmmeter between terminals #3 and #23 on the breakout box.

The ohmmeter should read approximately 0 ohms.

OK - No Fault Found

Not OK - Checking the breakout box

------------------------

Checking the breakout box












- Ignition off.
- Disconnect the adapter from the ECC control module and from the ECC control module connector.
Check the internal cables in the breakout box for the ground terminal which deviated from 0 ohms.
Connect an ohmmeter between:
- breakout box terminal #3 and adapter connector terminal #3
- breakout box terminal #23 and adapter connector terminal 23









The ohmmeter should read 0 ohms.

OK - Replacing the component

Not OK - Replacing the component

------------------------

Replacing the component
- Try a new ECC control module

Select "Continue" when the component has been replaced.

Continue - Verification

------------------------

Checking for an open-circuit
Check the ground lead between the 30 pin connector terminal #3 (ECC control module side) and ground terminal relay box 15/14, ground rail D8, for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault









Is there an open-circuit in the cable?

Yes - Remedying an open-circuit

No - Checking for an open-circuit

------------------------

Checking for an open-circuit
Check for an open-circuit between ground rail D10 and the chassis according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.





Select Continue when the fault has been remedied.

Continue - Verification

------------------------

Remedying an open-circuit
- Remedy the open-circuit.

Select Continue when the fault has been remedied.

Continue - Verification

------------------------

Replacing the component
- Disconnect adapter 981 3194 Replaced by 9511495 981 3194 Replaced by 951 1495 from the breakout box 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428. Check the relevant leads in the breakout box and adapter to establish where the fault is.
Replace the breakout box or the adapter.

Select Continue when the fault has been remedied.

Continue - Checking ground terminals

------------------------

Self-adjustment of the shutter motor end position
Activate the self-adjustment function with VIDA according to Self adjustment of damper motor limit positions Self Adjustment Of Damper Motor Limit Positions.





Select "Continue" when self-adjustment is complete.

Continue - Verification

------------------------

Verification




Verification

Hint: Check after repair that the fault has been rectified.












- Ignition off
- Reconnect connectors, reinstall components etc.
- ECC- control module connected.
- Engine running
- VCT2000 connected to the data link connector (DLC).
Establish communication with the ECC -system.





Select "Continue".

Continue - Verification, continued

------------------------

Verification, continued
- For further information about self-adjustment, see Self adjustment of damper motor limit positions Self Adjustment Of Damper Motor Limit Positions.
Click the VCT2000 symbol to activate the self adjustment function.





Select "Continue".

Continue - Verification, continued

------------------------

Verification, continued
Click on the VCT2000 symbol to read off the diagnostic trouble codes (DTCs).





Select "Continue".

Continue - Verification, continued

------------------------

Verification, continued
Erase diagnostic trouble codes (DTCs).





Select "Continue".

Continue - Verification, continued

------------------------

Verification, continued
Check that diagnostic trouble codes (DTCs) do not recur.





Do the diagnostic trouble codes (DTCs) recur?

Yes - VERIFICATION FAILED

No - VERIFIED

------------------------

VERIFICATION FAILED - Fault-tracing information

VERIFIED - FAULT FOUND

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should be diagnosed and remedied. Since this is not the case the fault-tracing process has failed.
Complete the fault-tracing for those fault or try again.

Do you want to terminate fault-tracing at this time?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

FAULT-TRACING FAILED - FAULT-TRACING FAILED

Attempt New Test - Connecting the breakout box

-------------------------------------------------












- Ignition off
- Connectors connected
- ECC control module connected.
Connect the breakout box between the ECC control module and the wiring.






FAULT FOUND - Checking voltage

FAULT-TRACING FAILED - Checking voltage

No Fault Found - Checking voltage

DONE - Checking voltage

-------------------------------------------------

Checking voltage




- Ignition off
- Generator D+ must be OK
- The blower fan switch must not be in position 0
- The air conditioning (A/C) button must be in the ON position (the green LED is on).
Connect a voltmeter between terminals 3 (0 V) and 26 on the breakout box.
- Engine running
- The voltage must be approximately battery voltage when the air conditioning (A/C) button is in the ON position (the green LED is lit).









Is the voltage OK?

Yes - Checking for an open-circuit

No - Checking for a short-circuit

-------------------------------------------------

Checking for an open-circuit
Check the cable between ECC control module connector terminal 26 and pressure switch connector terminal 1 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.









Is there an open-circuit in the cable?

Yes - Verification

No - Replacing the component

-------------------------------------------------

Checking for a short-circuit








- Ignition off
- Disconnect the connector for the pressure switch.
Check the cable between pressure switch connector terminal 1 and ECC control module connector terminal 26 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.









Is there an short-circuit in the cable?

Yes - Verification

No - Replacing the component

-------------------------------------------------

Replacing the component
- Replace the ECC control module according to Control module, climate Control Module, Climate.

Select "Continue" when the component has been replaced.

Continue - Self-adjustment of the shutter motor end position

-------------------------------------------------

Self-adjustment of the shutter motor end position
- For further information about self-adjustment, see Self adjustment of damper motor limit positions Self Adjustment Of Damper Motor Limit Positions.
Activate the self-adjustment function by clicking on the VCT 2000 symbol.





Select "Continue" when self-adjustment is complete.

Continue - Verification

-------------------------------------------------

Verification




Verification

Hint: Check after repair that the fault has been rectified.












- Ignition off.
- Connect the connectors, reinstall components etc.
- ECC control module connected.
- Engine running.
- A/C switch ON (green LED lit).

Does the symptom recur?

Yes - VERIFICATION FAILED

No - VERIFIED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information
Information
FAULT-TRACING FAILED - FAULT-TRACING FAILED

Attempt New Test - Connecting the breakout box

-------------------------------------------------