Example 3
Example 3
Socket type housing p/n 3523276-8
Replacement of cable terminals
Remove the connector cover
- Pull the rubber sleeve back on the cables.
- Keep both catches pressed in (one on each side) and pull the connector cover up.
- Remove the connector cover from the housing.
Open the housing
Release the secondary locking catches (one on each side) as follows:
- Insert a narrow screwdriver blade as shown. Carefully bend back the catch at the edge and push the secondary locking slightly forwards (approx. 1 mm).
Extract the cable terminal
Follow the instructions in when the cavity opening has two extraction grooves.
Crimp new cable terminal
Crimp the cable terminal as in Crimping a cable terminal. Do not forget to install a new seal on the cable.
Insert the new cable terminal in the housing
NOTE: The housing secondary locking must be slightly open as in (ND2).
- Insert the new cable terminal in the housing from the cable side checking that it is in the correct cavity. A "click" indicates the catch has engaged.
Close the housing
Secondary locking
Press the secondary locking catches (one on each side) slightly to their original position.
Check
- Carefully pull on the cables to check the terminal is firmly attached.
Reassemble the connector
- Replace the connector cover by depressing the locking catches (one on each side).
Check that the catches have engaged properly.
- Push rubber seal into place.