Activating Functions
Activating functions
Activation routines
The following can be activated in the immobilizer.
Activation of:
1. VGLA output
2. Antenna signal
3. Indicator lamp
4. Starter relay
5. Relay 1
6. VERLOG signal (applies only to MSA15.5 engine management systems).
Select an alternative.
1 - Activating the VGLA output
2 - Activating the antenna signal
3 - Indicator lamp
4 - Starter relay
5 - Activating relay 1
6 - Verlog signal
-------------------------------------------------
Activating the VGLA output
Activating the VGLA output
VGLA output
- Ignition on.
The VGLA output can only be activated if the key in the ignition is approved.
The voltage level at the output then rises and remains high until activation is stopped by pressing stop.
Other information:
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.
- For further information about activations see Activating components and functions Activating Components And Functions.
Are there any further activations to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------
Activating the antenna signal
Activating the antenna signal
Antenna signal
- Ignition on.
The control module transmits a signal (with a frequency of 125 kHz on #9 and #10) for 4 seconds. Cannot be interrupted.
The frequency can be measured using a suitable multimeter with a frequency meter.
Other information:
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.
- For further information about activations see Activating components and functions Activating Components And Functions.
Is there any further programming to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------
Indicator lamp
Indicator lamp
Indicator lamp
- Ignition on.
Click the VCT 2000 symbol to activate the indicator lamp.
The indicator lamp flashes for 30 seconds.
Other information:
- For further information about activations see Activating components and functions Activating Components And Functions.
Is there any further programming to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------
Starter relay
Starter relay
Starter relay
- Ignition on.
Click the VCT 2000 symbol to activate the starter relay.
The starter relay is activated for 30 seconds.
Other information:
- For further information about activations see Activating components and functions Activating Components And Functions.
Is there any further programming to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------
Activating relay 1
Activating relay 1
Relay 1
- Ignition on.
The relay switches (clicks) on and off at a frequency of 0.5 Hz for 4 seconds. Cannot be interrupted.
Other information:
- For further information about activations see Activating components and functions Activating Components And Functions.
Is there any further programming to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------
Verlog signal
VERLOG signal
Verlog signal
- Ignition on.
The voltage level at the output is then low for 5 seconds.
Other information:
- For further information about activations see Activating components and functions Activating Components And Functions.
Is there any further programming to be carried out?
Yes - Attempt New Test
No - DONE
------------------------
Attempt New Test - Activation routines
DONE - DONE
-------------------------------------------------