Connecting the Breakout Box (DSA)
Connecting The Breakout Box. DSA
Special tools: 981 3194, 9813190
Connecting the breakout box to the DSA control module
- Ignition off
- Expose the DSA control module
- Remove the control module from the holder
- Disconnect the control module
- Check that the male and female terminals in the control module and the control module connector are intact and secure. Check that the wiring to the female terminals is properly secured to the pins
- In particular, check the terminal pins relevant to the diagnostic trouble code (DTC)/symptom
- Connect adapter 981 3194 (the 16-pin terminal) to the control module connector (wiring side). Connect breakout box 981 3190 to the adapter.