Operation CHARM: Car repair manuals for everyone.

CCM-0005









Condition
If control unit registers that signal from evaporator temperature sensor is more than 97% of excitation voltage (approximately 5 V), diagnostic trouble code CCM-0005 is displayed.

Condition
- Control unit assumes a substitute value equivalent to approximately 0°C (32°F).

Possible source
- Signal wire has open circuit or short circuit to voltage supply
- Contact resistance, oxidation or loose contact in connector
- Ground connection has open circuit or short circuit to voltage supply
- Defective evaporator temperature sensor.

Condition
- No cool air from A/C-system
- A/C compressor does not work or works intermittently
- Intermittent function of A/C-system.