CCM-0007
Condition
If control unit registers that signal from interior temperature sensor is more than 97% or is less than 2% of excitation voltage (approximately 5 V), diagnostic trouble code CCM-0007 is displayed.
Condition
- The control unit assumes a substitute value equivalent to 25°C (77°F).
Possible source
- Defective measuring instrument.
- Defective interior temperature sensor.
Condition
- Interior temperature does not match set value.