Current Too Low - Intermittent Fault
Current too low. Intermittent fault
Checking wiring and connectors
Caution! Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.
Check signal cable (+) between control module #A42 and heated oxygen sensor (HO2S) connector terminal 4 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check signal cable (-) between control module #A41 and heated oxygen sensor (HO2S) connector terminal 3 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information
- Connecting the breakout box/accessing the control module, see
- To access/replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals, see Signal specification Signal Description / Specification
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
DONE - DONE
-------------------------------------------------