UEM-0011
Condition
Diagnostic trouble code (DTC) UEM-0011 is stored if the upper electronic module registers that the signal in the movement sensor communication cable is low when the alarm is deactivated.
Condition
None.
Possible source
- Short-circuit to ground in the sensor communication cable.
- Defective sensor.
Condition
- Does not alarm the sensor.