Signal Too Low - Intermittent Fault
Signal too low. Intermittent fault
Checking wiring and connectors
Check the signal cable between control module terminal #A40 and engine coolant temperature (ECT) sensor terminal 2. Check for an intermittent short-circuit to ground.
Other information
- To access the control module, see Engine control module (ECM), replacing Service and Repair
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box
- To access or replace the engine coolant temperature (ECT) sensor, see Engine coolant temperature (ECT) sensor, replacing Service and Repair
- For information about signals see Signal specification Signal Description / Specification
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
DONE - DONE
-------------------------------------------------