Current Too High - Intermittent Fault
Current too high. Intermittent fault
Checking cables
Check signal cable (+) between control module #A42 and heated oxygen sensor (HO2S) connector terminal 4 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check signal cable (-) between control module #A41 and heated oxygen sensor (HO2S) connector terminal 3 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box
- To access the control module, see
- To access/replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals, see Signal specification Signal Description / Specification
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking cables
FAULT FOUND - DONE
DONE - DONE
-------------------------------------------------