Signal Too High - Intermittent Fault
Signal too high. Intermittent fault
Checking wiring and connectors
Check signal cable between control module #A22 (#A22) and mass air flow (MAF) sensor terminal 2 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information:
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box
- To access the control module, see
- To access/replace the Mass Air Flow (MAF) sensor, see
- For information about signals, see Signal specification Signal Description / Specification.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking wiring and connectors
DONE - DONE
FAULT FOUND - DONE
-------------------------------------------------