Checking The Power Supply, Climate Control Module
Checking the power supply, climate control module
Checking the cable
- Check the cable for the 30-supply between climate control module #A1 and the battery positive terminal. Check for contact resistance, an open-circuit and a short-circuit to ground
- Check the cable for the 15-supply between climate control module #A5 and the power supply. Check for contact resistance, an open-circuit and a short-circuit to ground.
Hint: Climate control module terminal #A5 is only supplied with power when the ignition is on (when the system relay for air conditioning (A/C) is activated).
Other information:
- To connect the breakout box, see Connecting the breakout box, climate control module Connecting The Breakout Box
- For information about signals, see Climate control signal specifications Signal Specification
- For further information about fuses etc, refer to Wiring diagrams
- For information about the system relay for the climate control module position, see Electrical / electronic system specifications [1][2]Specifications
- Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Was a fault detected?
Yes - Fault-tracing information
No - No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should be diagnosed and remedied. Since this is not the case the fault-tracing process has failed.
Complete the fault-tracing for those fault or try again.
Do you want to terminate fault-tracing at this time?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the cable
-------------------------------------------------