Programming and Relearning
Self-adjustment of damper motor end positions
Self-adjustment of damper motor end positions. Electronic climate control (ECC), Manual climate control (MCC), Standard (STD)
Note! Self-adjustment must be carried out if the control module or damper motor is replaced or the damper motor or its linkage has been removed. The indication LED on the climate control module panel will flash during adjustment.
Hint: During self-adjustment the control module runs the damper motors to their limit positions. The control module then stores the value returned from the position sensor for the damper motor. The control module is then able to operate the motor betweenthe limit positions during normal operation.
- Start the engine (the generator charges)
- Activate self-adjustment. The self-adjustment takes thirty seconds.
Note! Self-adjustment can only be carried out once in the same ignition cycle. To run the self-adjustment again, switch off the ignition, wait 10 seconds and start the engine again.
The indication LED stops flashing when the self-adjustment is complete.
Continue - FAULT FOUND
-------------------------------------------------