Signal Too Low
Signal too low
Checking wiring and components
Check cable between starter motor relay #2 and control module #B23 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box.
- To access/replace the control module, see the relevant service procedure.
- For information about signals, see Signal specification Signal Description / Specification.
Continue - Verification
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Checking wiring and components
FAULT-TRACING FAILED - FAULT-TRACING FAILED
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect connectors, reinstall components
- Operate the starter motor.
- Read off the signal from ignition switch.
It should be ON.
Is the signal ON?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------