Part 1
Add alarm function
Connecting the Volvo Communication Tool 2000 (VCT2000)
Connecting the Volvo Communication Tool 2000 (VCT 2000)
Connecting the Volvo Communication Tool 2000 (VCT 2000)
The VCT 2000 must be connected to both the VIDA PC and the data link connector (DLC) in the car to communicate with the control modules in the car.
For information about connection, see Connecting VCT2000 Connecting VCT2000.
Location of Components DSA, Data Link Connector DLC:
Continue - DONE
------------------------
DONE - Conditions
-------------------------------------------------
Conditions
Conditions
Conditions
- Ignition on.
Warning! The battery must supply sufficient voltage throughout the transfer.A battery charger should therefore be connected to the vehicle throughout the transfer process.
Warning! Leave VCT 2000 connected to the vehicle until VIDA displays that the program transfer is complete.
If the transfer is interrupted (this may occur if the connection between VCT 2000 and the vehicle is broken or if the battery discharges), the status of the control module may be indefinable. It is normally sufficient to switch the ignition on and off and to then try programming again to return to normal function.
In some cases it may be necessary to disconnect the control module and then switch of the ignition to return to normal function.
Caution! It is important that correct chassis number is supplied when ordering software. If an incorrect chassis number is supplied, the software may contain incorrect PIN codes. This will mean that the control module cannot be programmed.If programming fails, even though the correct software has been ordered, there may be an incorrect PIN code stored in VITaL.
Continue - DONE
------------------------
DONE - Communication test
-------------------------------------------------
Communication test
Verification of communication with the control module
Communication with the control module must be verified!
Please wait!
Numeric Result 0 - DONE
Numeric Result -32000 - Communication fault
Numeric Result -32008 - Communication fault
Numeric Result -33000 - Communication fault
Numeric Result 24577 - Communication fault
Numeric Result 25345 - Communication fault
Numeric Result 25419 - Communication fault
Numeric Result 25456 - Communication fault
Numeric Result 25468 - Communication fault
------------------------
Communication fault
The communication between VCT 2000 and the vehicle has failed for one of the following reasons:
- The battery voltage is too low.
- The control module does not respond.
- The ignition is off.
Ensure that:
Battery voltage exceeds 12 V.
The ignition is on.
Do you want to try to establish communication again?
Yes - Verification of communication with the control module
No - No Fault Found
------------------------
Communication fault
Communication failure
Communication between VIDA PC and VCT 2000 has failed for one of the following reasons:
- Ignition is OFF.
- The VST/VCT 2000 switch is not in position VCT 2000.
- VCT 2000 is not connected to the diagnostic connector.
- VCT 2000 is not connected to VIDA PC/selector switch.
- Communication problem in VIDA application and/or vehicle.
- Too low battery voltage.
Ensure that:
- Ignition is ON and selector switch is in position VCT 2000.
- VCT 2000 is properly connected to diagnostic connector inside vehicle and VIDA PC/selector switch.
- VCT 2000 and associated cables are functional.
- Battery voltage exceeds 12 V.
Do you want to make another attempt to establish communication?
Yes - YES
No - NO
------------------------
YES - Verification of communication with the control module
NO - No Fault Found
-------------------------------------------------
DONE - Identify the status of the VGLA control module
No Fault Found - DONE
-------------------------------------------------
Identify the status of the VGLA control module
Note! The status of the VGLA programming must be determined before the alarm settings are programmed.
- Ignition on.
Select the VCT2000 symbol to begin identifying the status of the control module.
A - Program the VGLA alarm settings
B - Information
-------------------------------------------------
Program the VGLA alarm settings
The VGLA control module has functions that allow alarm settings to be modified. The alternatives that are available are in the list box.
Caution! The lock and alarm system must be equipped with the remote control function if an Alarm is to be added. If the car does not have the remote control function it must be added. Select Exit and order the software package to add the remote control function before carrying out this programming.
Programming procedure
Select the desired setting from the list box and then Select Continue to program the different alarm settings and to receive more information about the different alternatives.
Other procedures:
1. Begin the programming procedure and make one setting at a time. Work from the top of the list in the box to the bottom
2. Read off all programmed alternatives
3. Exit without programming.
1 - Programming the alarm
2 - Read off the values of the programmed settings
3 - DONE
Numeric Result 0 - Programming the alarm
Numeric Result 1 - Programming the siren
Numeric Result 2 - Programming the length of time the siren will sound
Numeric Result 3 - Program the body type
Numeric Result 4 - Programming the turn signal lamp flash acknowledgement
Numeric Result 5 - Programming the key position type
Numeric Result 6 - Programming the delay interval for fuel tank filler cover locking
Numeric Result 7 - Programming the ultrasonic sensor
Numeric Result 8 - Programming the glass breakage sensor
Numeric Result 9 - Programming alarm deactivation for the immobilizer
Numeric Result 10 - Programming the tilt sensor
Numeric Result 11 - Programming the Immobilizer LED
Numeric Result 12 - Programming diagnostic trouble code (DTC) indication
Numeric Result 13 - Programming automatic alarm activation
Numeric Result 14 - Program key controlled alarm activation
Numeric Result 15 - Programming the panic alarm
Numeric Result 16 - Programming alarm deactivation via the central locking switch
Numeric Result 17 - Programming continuous alarm activation
Numeric Result 18 - Information about programming the lock function
-------------------------------------------------
Read off the values of the programmed settings
- Ignition on.
Select the VCT2000 symbol to read off the VGLA alarm settings.
Continue - Program the VGLA alarm settings
-------------------------------------------------
Information
Note! This is a new VGLA control module.The function for modifying settings cannot be used on a new, unprogrammed control module.
Order the correct software package for a newVGLA control module.
Continue - DONE
-------------------------------------------------
Programming the alarm
Note! This parameter displays whether the control module is configured for an alarm or not.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Alarm status, select the desired setting from the alternatives in the lower list window.
Caution! The lock and alarm system must be equipped with the remote control function if an Alarm is to be added. If the car does not have the remote control function it must be added. Select Exit and order the software package to add the remote control function before carrying out this programming.
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the siren
No - Information
-------------------------------------------------
Programming the siren
Note! This parameter displays whether the control module is configured for a siren or not. The setting must correspond to the equipment in the vehicle.The alarm must be activated before the siren function will work.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Siren, select the desired settings from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the length of time the siren will sound
No - Information
-------------------------------------------------
Programming the length of time the siren will sound
Note! This parameter controls the length of time the siren sounds when the alarm has been triggered. This function is market dependent. Contact the dealer if unsure about this function.Both the alarm and siren must be activated before the siren sound function will work.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Siren sound length, select the desired settings from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Program the body type
No - Information
-------------------------------------------------
Program the body type
Note! This parameter governs the type of car body the VGLA control module is programmed for.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Body type, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the turn signal lamp flash acknowledgement
No - Information
-------------------------------------------------
Programming the turn signal lamp flash acknowledgement
Note! This parameter controls the use of the turn signal lamp flash acknowledgement when the alarm is activated and deactivated. This function is market dependent. Contact the dealer if unsure about this function.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Turn signal lamp flash acknowledgement, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the key position type
No - Information
-------------------------------------------------
Programming the key position type
Note! This parameter displays whether the control module should detect if the key is in or out of the ignition switch (an extra switch is installed on the ignition switch for this purpose) or if the control module should detect that the ignition switch is in position 1. The setting must correspond to the equipment in the car. This function is market dependent. Contact the dealer if unsure about this function.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Key position type, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the delay interval for fuel tank filler cover locking
No - Information
-------------------------------------------------
Programming the delay interval for fuel tank filler cover locking
Note! This parameter controls whether there should be a delay of 10 minutes before the fuel tank filler cover is locked when the car is locked. This function is market dependent. Contact the dealer if unsure about this function.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Delay interval, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the ultrasonic sensor
No - Information
-------------------------------------------------
Programming the ultrasonic sensor
Note! Displays whether the control module is configured for an ultrasonic sensor or not.The alarm must be activated before the ultrasonic sensor function will work.
- Ignition on.
1. Select the VCT2000 symbol to begin the programming procedure
2. Read off the present value for the setting in the upper list box
3. If you want to modify the Ultrasonic sensor, select the desired setting from the alternatives in the lower list window.
Note! There is a sensor in each B-post if the vehicle is equipped with an ultrasonic sensor.
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.
Do you wish to continue to program the next setting?
Yes - Programming the glass breakage sensor
No - Information
-------------------------------------------------