Verification
Verification
HINT: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Activate reading the value from the manifold absolute pressure (MAP) sensor and the atmospheric pressure sensor.
Check the difference between the pressure readings. Check that the difference is not greater than 70 hPa. The fault has been remedied if the difference is 70 hPa or less. The function is faulty if the difference is greater than 70 hPa.
Is the difference 70 hPa or less?
YES: Refer to Diagnostic Trouble Code Descriptions. Diagnostic Trouble Code Descriptions
NO: Refer to Fault-Tracing Information - Permanent Fault. Fault-Tracing Information - Permanent Fault