Operation CHARM: Car repair manuals for everyone.

Part 2






Programming a new combined instrument panel (Continued)

Programming the time display

Note! This parameter is used to set whether the clock will display the time as 12 or 24 hours.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Time display, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming initial zeroes

-------------------------------------------------

Programming initial zeroes

Note! The instrument panel can be set to display or not display the zeroes. When displaying zeroes, all the digits in front of the number of driven kilometers will be filled out with zero. When zeroes are not displayed, these positions are blank.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Initial zeros, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming the speed warning

-------------------------------------------------

Programming the speed warning

Note! This parameter is used to set the speed at which the combined instrument panel warns the driver.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Speed warning, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming the function high temperature warning for diesel engines

-------------------------------------------------

Programming the function high temperature warning for diesel engines

Note! This parameter is set if the indication for too high engine coolant temperature (ECT) for diesel engines is to be displayed.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the function, select the desired setting from the alternatives in the lower list window.
For diesel enginesthe function must be activated.
For gasoline enginesthe function must not be activated
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming fuel consumption calculation, offset

-------------------------------------------------

Programming the display for the outside temperature / trip computer function

Caution! If a display is not activated it must be programmed before the outside temperature or the trip computer will be displayed.

Note! A diagnostic trouble code (DTC) will be stored if programming is carried out when an outside temperature sensor is not installed.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Display type, select the desired setting from the alternatives in the lower list window.
If the combined instrument panel display is in kilometers, the kilometer display (metric) must be selected.
If the combined instrument panel display is in miles, the miles display (imperial) must be selected
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming the outside temperature display unit

-------------------------------------------------

Programming the outside temperature display unit

Note! Use this parameter to set the outside temperature unit to display readings in °C or °F.

Caution! This programming is only relevant if the display for outside temperature / trip computer function is activated.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Unit, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Programming the trip computer function

-------------------------------------------------

Programming the trip computer function

Note! This parameter is used to set whether the combined instrument panel has the trip computer function or not.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Trip computer function, select the desired settings from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the upper list box is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the upper list box is the desired value.





Continue - Information about programming the combined instrument panel

-------------------------------------------------

Programming fuel consumption calculation, offset

Warning! This setting affects the entire fuel calculation in the combined instrument panel. This setting can only be modified using specific information from the dealer.

Note! This parameter is used to set the trip computer's fuel consumption value. This value may need to be reprogrammed if the trip computer value does not correspond to the actual value.This programming is only relevant if the display is installed and the trip computer function is programmed.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Offset value, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.





Continue - Programming the displayed fuel level value, offset

-------------------------------------------------

Programming the displayed fuel level value, offset

Warning! This setting affects the total fuel consumption calculation in the combined instrument panel and the low fuel level warning function. Incorrect setting may result in no warning for low fuel level!This setting can only be modified using specific information from the dealer.

Note! This parameter is used to set the deviation from displayed fuel level sensor value. This value may need to be reprogrammed if the shape of the fuel tank has been changed.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Offset value, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.





Continue - Programming the type of engine management system for temperature display

-------------------------------------------------

Programming the type of engine management system for temperature display

Note! This parameter is used to program the engine management system the car is equipped with. The engine management systems transmits different temperature signals to the combined instrument panel. The correct type of engine management system must be programmed before the combined instrument panel can display the correct engine coolant temperature (ECT).




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Engine management system, select the desired setting from the alternatives in the lower list window

The following engine management systems are available:
- Diesel EDC 15.C, Melco 2
- EMS 2000 Bi-fuel
- EMS 2000.

Clarification of the engine management systems
- Diesel EDC 15C= D4192T3, D4192T4
- Melco 2= B4184SJ
- EMS 2000= Naturally aspirated engines and all turbocharged gasoline engines
- EMS 2000 Bifuel= Naturally aspirated engine with gas and gasoline operation.
1. Select the Start programming button to begin the programming procedure
2. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.





Continue - Programming the engine type

-------------------------------------------------

Programming the engine type

Note! This parameter is used to program which engine management system the car is equipped with. The correct type of engine management system must be programmed before the combined instrument panel can display the correct engine coolant temperature (ECT).




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. If you want to modify the Engine typesselect the desired setting from the alternatives in the lower list window. Two alternatives of engine type can be selected. Gasoline- (not Melco2) / diesel engineor gasoline engine Melco2.
Melco 2 = B4184SJ
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.





Continue - Programming the speedometer display

-------------------------------------------------

Programming the speedometer display

Note! This parameter is used to program the speedometer display according to type and market.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Speedometer type, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.





Continue - Programming time delay

-------------------------------------------------

Programming time delay

Warning! This setting affects the function for calculating low gas level in the combined instrument panel. Incorrect setting can result in gas power being connected at the incorrect level! This setting can only be modified using specific information from the dealer.

Note! A time delay begins when the combined instrument panel detects that the gas level in the fuel tank is low (via the signal from the gas level sensor). After the time delay, the combined instrument panel transmits a signal to the LPG control module indicating low gas level and the engine control module (ECM) for EMS2000 switches to gasoline power. This parameter is used to program the length of the time delay.




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. Read off the current value for the setting in the upper list box
3. To modify the Time display, select the desired setting from the alternatives in the lower list window
4. Select the Start programming button to begin the programming procedure
5. Check that the new setting in the middle list window is correct.
If the selected setting is incorrect, click on the desired value in the lower list box again. Then click on the Start programming button. Check that the new value in the middle list window is the desired value.









Continue - Information

-------------------------------------------------

Selecting the instrument type
Select the instrument type in order to program the correct values.
1. Combined instrument panel calibrated only in km
2. Combined instrument panel calibrated in miles and km.

Select the desired alternative above.

1 - Programming the total mileage (km)

2 - Programming the total mileage (miles)

-------------------------------------------------

Programming the total mileage (km)




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. The odometer setting can be programmed between 0 and 999,999 km. It is only possible to program this parameter onceand then only if the reading is below 100 km. The actual stored mileage is displayed in the upper field
3. Entered the desired mileage in the white field using the keyboard.

Caution! Do not enter zeroes "0" before the actual mileage.Programming can only be carried out ONCE so take care when setting the mileage.

4. Confirm the entered mileage! Click cancel if the selected value is incorrect
5. Confirm again
6. Select the Start programming button to begin the programming procedure
7. When programming is complete the programmed mileage is displayed in the field.





Continue - Program a new combined instrument panel

-------------------------------------------------

Programming the total mileage (miles)




- Ignition on.
1. Click the VCT2000 symbol to activate the programming procedure
2. The odometer setting can be programmed between 0 and 621,000 miles. It is only possible to program this parameter onceand then only if the reading is below 100 miles. The actual stored mileage is displayed in the upper field
3. Entered the desired mileage in the white field using the keyboard.

Caution! Do not enter zeroes "0" before the actual mileage.Programming can only be carried out ONCE so take care when setting the mileage.

4. Confirm the entered mileage! Click cancel if the selected value is incorrect
5. Confirm again
6. Select the Start programming button to begin the programming procedure
7. When programming is complete the programmed mileage is displayed in the field.





Continue - Program a new combined instrument panel

-------------------------------------------------

Information





Note! If the procedure is completed but a setting subsequently needs to be modified, the software to modify the settings must be ordered.

Continue with more programming or read off programmed data?

Yes - Information about programming the combined instrument panel

No - DONE

-------------------------------------------------