Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking cables and connectors
Check signal cable between control module #A5 (#A5) and mass air flow (MAF) sensor connector terminal 1 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults. The Intake Air Temperature (IAT) sensor is integrated into the Mass Air Flow (MAF) sensor
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5254T2 Connecting the Test Box.
- To access/replace the Mass Air Flow (MAF) sensor, Service and Repair
- For information about signals on 5-cyl, see Signal specification Signal Specification.
- For information about signals on 6-cyl, see Signal specification Signal Specification.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Exit fault-tracing
------------------------
Attempt New Test - Checking cables and connectors
-------------------------------------------------