Fault-Tracing
Fault tracing DEM-P093711
Checking the connectors and leads
- Ignition off
- Check the connector between the Differential Electronic Module (DEM) and the temperature sensor with respect to contact resistance and oxidation.
- Check connector A with respect to depressed or damaged pins, contact resistance and oxidation.
Hint: Read the temperature sensor signal to check the function.
Remedy as necessary.
Other information:
- Signal specification
- Temperature / pressure sensor active on demand coupling (AOC), replacing
- Differential electronic module (DEM), replacement
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on
Read the temperature.
Check that the value is appropriate by comparing it with the ambient temperature.
Is the temperature OK?
Yes - Troubleshooting procedure complete
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit Fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the connectors and leads
-------------------------------------------------