P0120
System/ComponentThrottle Position Sensor
Fault Code
P0120
Fault Type
Plausibility No
Signal Yes
Minimum Threshold Yes
Maximum Threshold Yes
Monitoring Method
Voltage range check
Signal Type
None
Operating Range
0 to 5V
Time Length and Frequency for Monitoring/Diagnosis
0.01 sec/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
U < 0.195v
U > 4.8V