P0133
System/ComponentOxygen Sensor (2) (upstream Cat.-system) cylinder 1-3
Fault Code
P0133 Response Time
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
time range check
Signal Type
ECM internal signal/value computation or comparison
Operating Range
Catalyst temp.
Time Length and Frequency for Monitoring/Diagnosis
100 sec/once per trip
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM)
Comparison of each measured response time (lean and rich) to predetermined maximum map values which depends on engine speed and load. If sum (measured times) during 115 lambda controller cycles is > than sum (max. map values) a fault will be detected.
max. map values for lean and rich [ms]
eng.speed(rpm) 800 1120 1536 2112 2816 3264
49 1787 1526 1144 883 643 823
2389 2008 1506 1185 1084 1044
71 1747 1486 1064 863 582 763
2289 1907 1405 1104 843 964
93 1727 1405 1084 944 843 843
2108 1526 1144 984 843 904
125 1466 1285 984 863 703 703
1405 1124 843 763 643 723
169 1446 1084 803 723 602 562
1426 944 683 602 562 542
218 1225 964 723 683 562 542
1185 843 562 542 502 502
289 1044 843 683 582 502 502
1004 723 562 462 482 482
419 944 803 602 522 462 462
944 823 602 522 502 502