P0134
System/ComponentOxygen Sensor (2) (upstream Cat.-system) cylinder 1-3
Fault Code
P0134 Heater power
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Plausibility check
Signal Type
ECM internal signal/value computation or comparison
Operating Range
Closed loop
Time Length and Frequency for Monitoring/Diagnosis
0.02 sec/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM)
Checking gap between lean voltage and rich voltage (min. = 1V)